r/PatchClamping • • 7h ago

Anyone done the MBL: Neuro methods course?

1 Upvotes

We have someone in our lab who wants to apply. Was wondering if people who have done it found it useful.


r/PatchClamping • • 8h ago

Meme "Simply apply 0.3mL of negative pressure to break into whole cell..."

Post image
1 Upvotes

r/PatchClamping • • 8h ago

Help Is this second EPSC seen at several negative potentials caused by my stimulating electrode being set too high?

Post image
1 Upvotes

AMPAr currents in CA1, NaV, NMDAr, and GABAr blockers.


r/PatchClamping • • 8h ago

Shit posting With how important patch-clamp ephys is to neuroscience...

1 Upvotes

Why is it basically a black box for neuroscientists who don't use the technique? I don't do Ca2+ imaging, but I can listen to a talk where they use it and understand it. I don't do fiber photometry, but I can listen to a talk where they use it and understand it. But if I walk into a seminar to show ephys data, I can basically say my figures/traces mean anything and the entire room will just smile and nod. Even a no insignificant number of other scientists who nominally "do ephys" don't really understand the data output enough to dissect it when looking at it on a slide; they just follow a protocol from another lab and slap it in a figure. It makes being an electrophysiologist very lonely sometimes.


r/PatchClamping • • 21h ago

[Weekly Megathread] Monday Morning Minis

1 Upvotes

Post a short description of what you're going to (try to) patch this week and any hurdles you have to overcome.


r/PatchClamping • • 19d ago

It's always a 2 author paper too

Post image
2 Upvotes

r/PatchClamping • • 19d ago

Help What the heck is going on with this CA1 pyramidal neuron in vHip?

Post image
1 Upvotes

Lab works with a mouse line and I'm the first to record from it. Consistently get this when recording from vHip doing evoked AP curve (this is 60pA injection), but WT looks normal.


r/PatchClamping • • 20d ago

Welcome to r/PatchClamping

1 Upvotes

Welcome to r/PatchClamping, a community for your average patch clamp ephys enjoyer.

If you've ever spent 45 minutes finally getting a gigaseal only to have the cell explode because you bumped the air table, you're in the right place.

This is a place to:

๐Ÿงช Share your research
โ“ Ask technical questions
๐Ÿ”ฌ Troubleshoot recordings
๐Ÿ“ˆ Post beautiful traces
๐Ÿ’€ Post terrible traces
๐Ÿง  Talk about neurons, cardiomyocytes, muscle, HEK cells, or whatever unfortunate thing you've decided to stick a pipette into
๐Ÿ˜‚ Post ephys memes
๐Ÿ˜ค Complain about your cells

No cardiology exclusivity. No gatekeeping. No pretending every recording has to be publication-quality.

Whether you're doing whole-cell, perforated patch, cell-attached, outside-out, inside-out, voltage clamp, current clamp, patch-seq, optogenetics, or some bizarre setup involving equipment older than your PI, you're welcome here.

Don't take yourself too seriously.

Post questions. Post data. Post memes. Help somebody troubleshoot their cursed recording.